单端行波故障测距的组合方法研究A Combined Method for Single-Ended Traveling Wave Fault Location
梁睿;孙式想;
摘要(Abstract):
单端辐射状电网发生单相接地故障时,单端行波故障测距的关键是正确识别来自故障点的反射波、对端母线的反射波及健全线路的反射波。行波零模波速具有较强的依频特性,而线模波速较稳定。由于零模波速的不稳定性,当取其为固定值时,导致基于线模、零模波速差的单端行波故障测距精确度不够。针对此问题,首先利用神经网络训练学习,估算出零模波速,基于线模、零模波速差得到初步故障距离,以此初步故障距离从线模行波突变波头中找出故障点反射波头及对端母线反射波头,再把线模波速代入相应的测距公式得到精确故障距离。利用PSCAD/EMTDC搭建仿真模型,对不同的故障情况进行仿真,均验证了该方法具有较高的测量精度和可靠性。
关键词(KeyWords): 波速差;小波变换;神经网络;波头识别;故障测距
基金项目(Foundation): 国家自然科学基金资助项目(51107143);; 中央高校基本科研业务费专项资金资助(2011QNA19)~~
作者(Author): 梁睿;孙式想;
Email:
DOI: 10.13335/j.1000-3673.pst.2013.03.011
参考文献(References):
- [1]季涛.中性点非有效接地系统行波故障测距技术[M].北京:北京理工大学出版社,2008:46-56.
- [2]Borghetti A,Bosetti M,Nucci C A,et al.Integrated use of time-frequency wavelet decompositions for fault location in distribution networks:theory and experimental validation[J].Transactions on Power Delivery,2010,25(4):3139-3146.
- [3]林圣,何正友,陈鉴,等.基于行波时频特征的单端故障测距方法[J].电网技术,2012,36(1):258-264.Lin Sheng,He Zhengyou,Chen Jian,et al.A single terminal fault location method based on time-frequency characteristic of traveling wave[J].Power System Technology,2012,36(1):258-264(in Chinese).
- [4]邬林勇,何正友,钱清泉.单端行波故障测距的频域方法[J].中国电机工程学报,2008,28(25):99-104.Wu Linyong,He Zhengyou,Qian Qingquan.A frequency domain approach to single-ended traveling wave fault location[J].Proceedings of the CSEE,2008,28(25):99-104(in Chinese).
- [5]Ji Zhigang,Zhang Peijun.Application of wavelet neutral network and rough set theory to forecast mid-long-term electric power load[C]//Proceedings of the First International Workshop on Education Technology and Computer Science.Wuhan:IEEE,2009:1104-1108.
- [6]张帆,潘贞存,马琳琳,等.基于模量行波传输时间差的线路接地故障测距与保护[J].中国电机工程学报,2009,29(10):78-83.Zhang Fan,Pan Zhencun,Ma Linlin,et al.Transmission line fault location and protection based on the gap between zero mode and aerial mode traveling wave propagation time[J].Proceedings of the CSEE,2009,29(10):78-83(in Chinese).
- [7]郑州,吕艳萍,王杰,等.基于小波变换的双端行波测距新方法[J].电网技术,2010,34(1):203-207.Zheng Zhou,LüYanping,Wang Jie,et al.A new two-terminal traveling wave fault location method based on wavelet transform[J].Power System Technology,2010,34(1):203-207(in Chinese).
- [8]李廷伟,姬广展,王鹰,等.一种改进的输电线路双端行波故障测距系统[J].电网技术,2008,32(1):90-92.Li Tingwei,Ji Guangzhan,Wang Ying,et al.An improved double traveling wave fault location system for transmission line[J].Power System Technology,2008,32(1):90-92(in Chinese).
- [9]覃剑,陈祥训,郑健超.行波在输电线上传播的色散研究[J].中国电机工程学报,1999,19(9):27-32.Qin Jian,Chen Xiangxun,Zheng Jianchao.Study on dispersion of travelling wave in transmission line[J].Proceedings of the CSEE,1999,19(9):27-32(in Chinese).
- [10]李友军,徐丽娜.电力系统接地短路故障中零模分量的依频关系分析[J].继电器,2007,35(15):4-8.Li Youjun,Xu Lina.Relationship between earth mode surge and frequency on power system earth fault[J].Relay,2007,35(15):4-8(in Chinese).
- [11]张怿宁,徐敏,刘永浩,等.考虑波速变化特性的直流输电线路行波故障测距新算法[J].电网技术,2011,35(7):227-232.Zhang Yining,Xu Min,Liu Yonghao,et al.A novel travelling wave fault location algorithm for HVDC transmission lines considering variation characteristics of wave speed[J].Power System Technology,2011,35(7):227-232(in Chinese).
- [12]束洪春,邬乾晋,张广斌,等.基于神经网络的单端行波故障测距方法[J].中国电机工程学报,2011,31(4):85-92.Shu Hongchun,Wu Qianjin,Zhang Guangbin,et al.Single terminal traveling wave fault location method based on ANN[J].Proceedings of the CSEE,2011,31(4):85-92(in Chinese).
- [13]郑健超,陈祥训,覃剑,等.验证小波变换行波故障测距法的现场试验[J].电网技术,2001,25(3):26-29.Zheng Jianchao,Chen Xiangxun,Qin Jian,et al.Field short-circuit test to validate travelling wave fault location using wavelet transform[J].Power System Technology,2001,25(3):26-29(in Chinese).
- [14]马丹丹,王晓茹.基于小波模极大值的单端行波故障测距[J].电力系统保护与控制,2009,37(3):55-59.Ma Dandan,Wang Xiaoru.Single terminal methods of traveling wave fault location based on wavelet modulus maxima[J].Power System Protection and Control,2009,37(3):55-59(in Chinese).
- [15]Mohamed S S,EL-Saadany E F,Abdel-galil T K.ANN-based technique for fault location estimation using TLS-ESPRIT[C]//IEEE Micro-Nano Mechatronics and Human Science.Ontario,Canada:IEEE,2003:1090-1094.
- [16]Magnago F H,Abur A.Fault location using wavelets[J].IEEE Trans on Power Delivery,1998,13(4):1475-1480.
- [17]贾清泉.非有效接地电网选线保护技术[M].北京:国防工业出版社,2007:14-50.
- [18]施围.电力系统过电压计算[M].西安:西安交通大学出版社,1988:66-78.
- [19]黄雄,王志华,尹项根.高压输电线路行波测距的行波波速确定方法[J].电网技术,2004,28(19):34-37.Huang Xiong,Wang Zhihua,Yin Xianggen.Travelling wave velocity measurement in fault location based on travelling wave for high voltage transmission line[J].Power System Technology,2004,28(19):34-37(in Chinese).
- [20]Zheng Xiuyu,Li Xiaoming,Ding Jianyong,et al.Study on impedance-traveling wave assembled algorithm in one-terminal fault location system for transmission lines[J].IEEE DRPT,2008:1723-1726.