基于Cassie模型和L_(3/4)范数的串联电弧故障检测方法A Series Arc Fault Detection Method Based on Cassie Model and L_(3/4) Norm
曲娜;王建辉;刘金海;吴丰成;
摘要(Abstract):
在民用交流电系统中,发生串联电弧故障时,电流一般较小达不到断路器阈值,而且在某些情况下,正常工作状态电流与电弧故障电流波形非常相似,难以检测,易导致电气火灾的发生。利用Cassie模型对串联电弧故障进行模拟,分别得到线性负载和非线性负载条件下时域电流波形,并利用傅立叶变换得到电流幅值频谱。对比可知,电弧故障状态下线性负载电流波形和正常工作状态下非线性负载电流波形均会出现零休;电弧故障状态下无论是线性负载还是非线性负载电流幅值频谱均会出现谐波且与正常工作状态电流幅值频谱具有不同的特点。利用基于L_(3/4)范数正则化的稀疏表示算法实现电弧故障检测,通过仿真说明该方法具有较好的稀疏性和准确性。
关键词(KeyWords): 电弧故障;Cassie模型;电流幅值频谱;稀疏表示;L3/4范数
基金项目(Foundation): 国家自然科学基金(61473069);; 辽宁省教育厅科学研究项目(L201742)~~
作者(Author): 曲娜;王建辉;刘金海;吴丰成;
Email:
DOI: 10.13335/j.1000-3673.pst.2017.3091
参考文献(References):
- [1]Bizjak G,Zunko P.Circuit breaker model for digital simulation based onMayr`sandCassie’sdifferentialarcequations[J]. IEEE Transactions on Power Delivery,1995,10(3):1310-1315.
- [2]King-JetTseng,YaomingWang,D.MahindaVilathgamuwa.An experimentallyverifiedhybridCassie-Mayrelectricarcmodelfor powerelectronicssimulations[J]. IEEETransactionsonPower Electronics,1997,12(3):429-436.
- [3]姜斌峰,王莉.低压交流电线故障电弧模型研究[J].电力系统及其自动化学报,2009,21(4):20-24.Jiang Binfeng,Wang Li.Research on arc model in AC low-voltage electrical wire fault[J].Proceedings of the CSU-EPSA,2009,21(4):20-24(in Chinese).
- [4]Lauri Kumpulainen,Matti Lehtonen.Preemptive arc fault detection techniquesinswitchgearandcontrolgear[J].IEEETransactionson Industry Applications,2013,49(4):1911-1918.
- [5]Riccardo Grassetti,Roberto Ottoboni,Marco Rossi.Low cost arc fault detectioninaerospaceapplications[J]. IEEEInstrumentation&Measurement Magazine,2013,10:37-42.
- [6]ShiLi.Studyoflowcostarcfaultcircuitinterrupterbasedon MCU[J].InternationalJournalofControlandAutomation,2015,8(10):25-34.
- [7]AnilYarmasu,YinniCao,GuangjunLiu.Aircraftelectricsystem intermittent arc fault detection and location[J].IEEE Transactions on Aerospace and Electronic Systems,2015,51(1):40-51.
- [8]Alireza Khakpour,Steffen Franke,Dirk Uhrlandt.Electrical arc model basedonphysicalparametersandpowercalculation[J]. IEEE Transactions on Plasma Science,2015,43(8):2721-2728.
- [9]郭凤仪,王鑫,刘艳丽.基于Mayr模型改进的适用于串联故障电弧的新模型[J].电工电能新技术,2015,34(2):67-71.Guo Fengyi,Wang Xin,Liu Yanli.New improved model for series arc faultbasedonMayrmodel[J].AdvancedTechnologyofElectrical Engineering and Energy,2015,34(2):67-71(in Chinese).
- [10]Nikola L.Georgijevic,Marko V.Jankovic.The detection of series arcfaultinphotovoltaicsystemsbasedonthearccurrent entropy[J].IEEE Transactions on Power Electronics,2016,31(8):5917-5930.
- [11]马少华,鲍洁秋,蔡志远.基于信息维数和零休时间的电弧故障识别方法[J].中国电机工程学报,2016,36(9):2572-2579.Ma Shaohua,Bao Jieqiu,Cai Zhiyuan.A novel arc fault identification methodbasedoninformationdimensionandcurrentzero[J].Proceedings of the CSEE,2016,36(9):2572-2579(in Chinese).
- [12]张春燕.基于电弧模型仿真的电气火灾智能算法分析[D].杭州:浙江大学,2016.
- [13]Giovanni Artale,Antonio Cataliotti.Arc fault detection method based onCZTlow-frequencyharmoniccurrentanalysis[J]. IEEE TransactionsonInstrumentationandMeasurement,2017,66(5):888-896.
- [14]黄忠霖.电工学的Matlab实践[M].北京:国防工业出版社,321-323.
- [15]Na Qu,Jianhui Wang,Jinhai Liu.Composite fire detection system usingsparserepresentationmethod[J].MathematicalProblemsin Engineering,2017(2017):1-8.
- [16]刘官耕,杜松怀,苏娟,低压电弧故障防护技术研究与发展趋势[J].电网技术,2017,41(1):305-313.LiuGuangeng,DuSonghuai,SuJuan.ResearchonLVarcfault protection and its development trends[J].Power System Technology,2017,41(1):305-313(in Chinese).
- [17]刘晓明,赵洋,曹云东.基于多特征融合的交流系统串联电弧故障诊断[J].电网技术,2014,38(3):795-801(in Chinese).Liu Xiaoming,Zhao Yang,Cao Yundong.Muti-feature fusion based diagnosisofseriesarcfaultsinACsystem[J]. PowerSystem Technology,2014,38(3):795-801(in Chinese).
- [18]刘柱揆,丁心志,许守东.开关柜电弧故障及其测量方法研究[J].电网技术,2017,41(4):1345-1349.Liu Zhukui,Ding Xinzhi,Xu Shoudong.Research on switchgear arc discharge fault and its measurement[J].Power System Technology,2017,41(4):1345-1349(in Chinese).