直流电压下矿物油和天然酯中纤维颗粒运动及成桥特性的差异Different Motion and Bridging Characteristics of Fiber Particles in Mineral Oil and Natural Ester Under DC Voltage
但敏;郝建;廖瑞金;李彦青;杨丽君;
摘要(Abstract):
纤维颗粒是运行变压器中绝缘油品质的首要污染者,以矿物油和天然酯为研究对象,在相同直流电场作用下,对不同板-板电极距离下油中纤维颗粒的运动及成桥特性进行了对比分析。研究结果表明:当直流电场相同时,与天然酯相比,矿物油中纤维颗粒运动更快,更容易形成完整的"纤维颗粒桥";矿物油中的"纤维颗粒桥"呈现与电场线方向平行的细圆柱状,而天然酯中"纤维颗粒桥"呈现三角锥形;随着板-板电极距离的增大,矿物油中形成最初"浅桥"所需的时间增大,"纤维颗粒桥"的密度减小,而天然酯则相反。颗粒的存在增大了绝缘油的泄漏电流,但2种油泄漏电流的变化趋势受电极距离的影响不同,天然酯的泄漏电流不易受颗粒影响。自直流加压至撤去电压后,2种绝缘油中的"纤维颗粒桥"均呈现动态变化的4个阶段:颗粒急剧运动阶段、完整"纤维颗粒桥"逐渐形成阶段、"纤维颗粒桥"密度逐渐增大阶段、"纤维颗粒桥"消散阶段。此外,研究发现"纤维颗粒桥"加压时的形成及撤去电压后的消散与电流陡增及陡降存在密切关系。
关键词(KeyWords): 直流电压;矿物油;天然酯;板-板电极;纤维颗粒
基金项目(Foundation): 中央高校基本科研业务费专项项目(2017CDJZR);; 国家电网公司总部科技项目(混合绝缘油变压器关键技术研究)~~
作者(Author): 但敏;郝建;廖瑞金;李彦青;杨丽君;
Email:
DOI: 10.13335/j.1000-3673.pst.2017.0808
参考文献(References):
- [1]Yamagishi A,Sampei H,Shirasaka Y,et al.Influence of micro particles in fluid on the impulse breakdown strength of low-viscosity silicone liquid on insulated electrode systems[D].Oxford:University of Oxford,1980.
- [2]CIGRE.WG 17/SC12 Effect of particles on transformer dielectric strength[S].Canada:J.AUBIN,2000.
- [3]李智,马强.500 k V变压器绝缘油的颗粒污染度监测[J].变压器,1999,36(9):31.Li Zhi,Ma Qiang.Monitoring the particle pollution degree of 500k V transformer’s insulation oil[J].Transformer,1999,36(9):31(in Chinese).
- [4]Rouse T O.Mineral insulating oil in transformers[J].IEEE Electrical Insulation Magazine,1998,14(3):6-16.
- [5]Zhou Y,Hao M,Chen G,et al.Study of the charge dynamics in mineral oil under a Non-homogeneous field[J].IEEE Transactions on Dielectrics and Electrical Insulation,2015,22(5):2473-2482.
- [6]Danikas M G.Breakdown of transformer oil[J].IEEE Electrical Insulation Magazine,1990,6(5):27-34.
- [7]俞问津,陈洁.蒙西电网电力用油中颗粒污染度的监测[J].内蒙古电力技术,2001,19(5):33-34.Yu Wenjin,Chen Jie.The supervision to the contamination by the foreign particle in the oil in west inner Mongolia power grid[J].Inner Mongolia Electric Power,2001,19(5):33-34(in Chinese).
- [8]乌日娜,刘江,陈洁,等.500 k V变压器和电抗器绝缘油颗粒污染度检测分析[J].内蒙古电力技术,2013,31(4):35-36.Wu Rina,Liu Jiang,Chen Jie,et al.Analysis of insulating oil particulate pollution in 500 k V transformer and reactor[J].Inner Mongolia Electric Power,2013,31(4):35-36(in Chinese).
- [9]李兴,张桂贤.500 k V变压器油颗粒度的试验分析[J].变压器,2009,46(6):40-41.Li Xing,Zhang Guixian.Test and analysis of graininess in 500 k V transformer oil[J].Transformer,2009,46(6):40-41(in Chinese).
- [10]赵瑞菊,谷金红.1000 k V变压器油颗粒污染度的监测分析[J].河南电力,2013(2):23-24.Zhao Ruiju,Gu Jinhong.Monitoring and analysis of the particle pollution degree of 1000 k V transformer oil[J].Henan Electric,2013(2):23-24(in Chinese).
- [11]Shekhar M,George C.Bridging in contaminated transformer oil under AC,DC and DC biased AC electric field[C]//2013 IEEE Electrical Insulation and Dielectric Phenomena,Shenzhen,China:2013:943-946.
- [12]Shekhar M,George C.Experimental studies of influence of DC and AC electric fields on bridging in contaminated transformer oil[J].IEEE Transactions on Dielectrics&Electrical Insulation,2015,22(1):152-160.
- [13]George C.Bridging phenomenon in contaminated transformer oil[C]//International Conference on Condition Monitoring and Diagnosis,Piscataway,US,2012:180-183.
- [14]Shekhar M.George C.Experimental studies of influence of different electrodes on bridging in contaminated transformer oil[J].IEEE Transactions on Dielectrics&Electrical Insulation,2015,22(5):2433-2441.
- [15]Shekhar M.Effect of different shapes of electrodes on bridging in contaminated transformer oil[C]//2014 IEEE Conference on Electrical Insulation and Dielectric Phenomena(CEIDP).Des Moines,IA,USA,2014:114-117.
- [16]Lu W,Liu Q.Effect of cellulose particles on impulse breakdown in ester transformer liquids in uniform electric fields[J].IEEE Transactions on Dielectrics&Electrical Insulation,2015,22(5):2554-2564.
- [17]廖瑞金,梁帅伟,杨丽君,等.天然酯与矿物油绝缘的加速热老化特性研究[J].中国电机工程学报,2008,28(25):20-24.Liao Ruijin,Liang Shuaiwei,Yang Lijun,et al.Study on the accelerated thermal aging of nature ester-paper insulation and mineral oil-paper insulation[J].Proceedings of the CSEE,2008,28(25):20-24(in Chinese).
- [18]Shekhar M,Golosnoy I O.Effect of Kraft paper barriers on bridging in contaminated transformer oil[C]//Electrical Insulation and Dielectric Phenomena(CEIDP),Des Moines Marriott Downtown Des Moines IA,USA,2014:110-113.
- [19]Zainuddi H.Investigation of bridging phenomena in ester oils contaminated with cellulose particles[C]//International Conference on Power,Energy,and Communication Systems(IPECS),Perlis,Malaysia,2015:408-413.
- [20]李金忠,张乔根.直流电压下油纸绝缘杂质纤维小桥的形成过程[J].高电压技术,2016,42(12):3901-3908.Li Jinzhong,Zhang Qiaogen.Generation process of impurity bridges in oil-paper insulation under DC voltage[J].High Voltage Engineering,2016,42(12):3901-3908(in Chinese).
- [21]李晓虎.植物绝缘油理化及电气性能的研究[D].重庆:重庆大学,2006.
- [22]廖瑞金,尹建国,杨丽君.矿物油-天然酯混合绝缘油减缓绝缘纸热老化速率机理的XPS研究[J].电工技术学报,2011,26(10):136-142.Liao Ruijin,Yin Jianguo,Yang Lijun.XPS study on the inhibition mechanism of newly developed mixed insulating oil on the thermal aging of insulating paper[J].Transactions of China Electrotechnical Society,2011,26(10):136-142(in Chinese).
- [23]陈义龙,齐波,李成榕.交直流复合电场下油纸绝缘界面电荷对沿面闪络电压的影响[J].电网技术,2014,38(4):1071.Chen Yilong,Qi Bo,Li Chengrong.Impact of interfacial charge of oil-pressboard insulation on surface flashover voltage under compound AC-DC electric field[J].Power System Technology,2014,38(4):1071(in Chinese).
- [24]Herbert A P.The motion and precipitation of suspensoids in divergent electric fields[J].Journal of Applied Physics,1915,22(7):869-871.
- [25]Birlasekaran S.The measurement of charge on single particles in transformer oil[J].IEEE Transactions on Electrical Insulation,1991,26(6):1094-1096.
- [26]Vincent C.Behavior of an oil-paper interface in presence of carbon particle contamination[C]//Conference Record of the 1994 IEEE International Symposium on Electrical Insulation,Pittsburgh,PAUSA,1994:534-537.