新一代大容量调相机在电网中的应用研究Study on Application of New Generation Large Capacity Synchronous Condenser in Power Grid
王雅婷;张一驰;周勤勇;李志强;姜懿郞;汤涌;吴俊玲;高超;屠竞哲;沈沉;
摘要(Abstract):
研究了新一代调相机在我国特高压直流送受端的应用。首先结合直流对于调相机的技术需求,研究了调相机模型,提出基于不同时间尺度的次暂态、暂态、稳态3种运行特性。然后,基于酒泉—湖南直流风火打捆送端,从增加系统短路比、降低新能源高压脱网风险、抑制稳态过电压等角度研究了调相机在特高压直流送端的应用效果;基于华东多直流馈入受端电网,从提高直流多馈入短路比、降低多回直流同时换相失败的风险、提升严重故障下的系统电压稳定水平等角度研究了调相机在特高压直流受端电网的应用效果。最后,从设备角度提出新一代调相机在运行维护、无功响应特性等方面相较于传统调相机的技术优势,旨在为调相机后续投入工程运行提供技术支撑。
关键词(KeyWords): 调相机;特高压直流;次暂态特性;强励;进相;新能源高压脱网;直流换相失败
基金项目(Foundation): 国家电网公司科技项目(XT71-15-026)~~
作者(Author): 王雅婷;张一驰;周勤勇;李志强;姜懿郞;汤涌;吴俊玲;高超;屠竞哲;沈沉;
Email:
DOI: 10.13335/j.1000-3673.pst.2016.0715
参考文献(References):
- [1]袁清云.特高压直流输电技术现状及在我国的应用前景[J].电网技术,2005,29(14):1-3.Yuan Qingyun.Present state and application prospect of ultra HVDC transmission in China[J].Power System Technology,2005,29(14):1-3(in Chinese).
- [2]曾庆禹.特高压交直流输电系统技术经济分析[J].电网技术,2015,39(2):341-348.Zeng Qingyu.Techno-economic analysis of UHVAC and UHVDC power transmission systems[J].Power System Technology,2015,39(2):341-348(in Chinese).
- [3]周孝信,鲁宗相,刘应梅,等.中国未来电网的发展模式和关键技术[J].中国电机工程学报,2014,34(29):4999-5008.Zhou Xiaoxin,Lu Zongxiang,Liu Yingmei,et al.Development models and key technologies of future grid in China[J].Proceedings of the CSEE,2014,34(29):4999-5008(in Chinese).
- [4]吴萍,林伟芳,孙华东,等.多馈入直流输电系统换相失败机制及特性[J].电网技术,2012,36(5):269-274.Wu Ping,Lin Weifang,Sun Huadong,et al.Research and electromechanical transient simulation on mechanism of commutation failure in multi-infeed HVDC power transmission system[J].Power System Technology,2012,36(5):269-274(in Chinese).
- [5]李新年,易俊,李柏青,等.直流输电系统换相失败仿真分析及运行情况统计[J].电网技术,2012,36(6):266-271.Li Xinnian,Yi Jun,Li Baiqing,et al.Simulation analysis and operation statistics of commutation failure in HVDC transmission system[J].Power System Technology,2012,36(6):266-271(in Chinese).
- [6]屠竞哲,张健,王建明,等.大规模直流异步互联系统受端故障引发送端稳定破坏的机理分析[J].中国电机工程学报,2015,35(21):5492-5499.Tu Jingzhe,Zhang Jian,Wang Jianming,et al.Mechanism analysis on the sending-side instability caused by the receiving-side contingencies of large-scale HVDC asynchronous interconnected power systems[J].Proceedings of the CSEE,2015,35(21):5492-5499(in Chinese).
- [7]屠竞哲,张健,刘明松,等.风火打捆直流外送系统直流故障引发风机脱网的问题研究[J].电网技术,2015,39(12):3333-3338.Tu Jingzhe,Zhang Jian,Liu Mingsong,et al.Study on wind turbine generators tripping caused by HVDC contingencies of windthermal-bundled HVDC transmission systems[J].Power System Technology,2015,39(12):3333-3338(in Chinese).
- [8]孙华东,张振宇,林伟芳,等.2011年西北电网风机脱网事故分析及启示[J].电网技术,2012,36(10):76-80.Sun Huadong,Zhang Zhenyu,Lin Weifang,et al.Analysis on serious wind turbine generators tripping accident in Northwest China power grid in 2011 and its lessons[J].Power System Technology,2012,36(10):76-80(in Chinese).
- [9]汪宁勃,马彦宏,丁坤,等.酒泉风电基地脱网事故频发的原因分析[J].电力系统自动化,2012,36(19):42-46.Wang Ningbo,Ma Yanhong,Ding Kun,et al.Analysis on root reasons of WTGs nuisance tripping in Jiuquan wind power base[J].Automation of Electric Power Systems,2012,36(19):42-46(in Chinese).
- [10]崔正湃,王皓靖,马锁明,等.大规模风电汇集系统动态无功补偿装置运行现状及提升措施[J].电网技术,2015,39(7):1873-1878.Cui Zhengpai,Wang Haojing,Ma Suoming,et al.Operation situation analysis and improvement measure study for dynamic reactive compensation equipment applied in large-scale wind power systems[J].Power System Technology,2015,39(7):1873-1878(in Chinese).
- [11]Sercan Teleke,Tarik Abdulahovic,Torbj?rn Thiringer,et al.Performance comparison of synchronous condenser and SVC[J].IEEE Transactions on Power Delivery,2008,23(3):1606-1612.
- [12]Katsuya Y,Mitani Y,Tsuji K.Power system stabilization by synchronous condenser with fast excitation control[C]//Proceedings International Conference on Power System Technology.Perth,Australia:IEEE,2000:1563-1568.
- [13]刘振亚,张启平,王雅婷,等.提高西北新甘青750 k V送端电网安全稳定水平的无功补偿措施研究[J].中国电机工程学报,2015,35(5):1015-1022.Liu Zhenya,Zhang Qiping,Wang Yating,et al.Research on reactive compensation strategies for improving stability level of sending-end of 750 k V grid in Northwest China[J].Proceedings of the CSEE,2015,35(5):1015-1022(in Chinese).
- [14]屠竞哲,刘明松,张健,等.酒泉—湖南?800 k V特高压直流输电工程送端系统安全稳定控制措施研究[R].北京:中国电力科学研究院,2014.
- [15]高超.扎鲁特~山东?800 k V特高压直流送端电压稳定及控制方案研究报告[R].北京:中国电力科学研究院,2015.
- [16]林伟芳,汤涌,卜广全.多馈入交直流系统短路比的定义和应用[J].中国电机工程学报,2008,28(31):1-8.Lin Weifang,Tang Yong,Bu Guangquan.Definition and application of short circuit ratio for multi-infeed AC/DC power systems[J].Proceedings of the CSEE,2008,28(31):1-8(in Chinese).
- [17]李兆伟,贺静波,张同尊,等.“8?8”多回入沪直流同时换相失败故障分析及思考[C]//2013年中国电机工程学会年会论文集.成都:中国电机工程学会,2013:1-7.